Matching the valve to the pipe size is quick, and in many plants that is how it is done. Sometimes it works well. Sometimes it leaves a valve that passes too little flow, or one so large that the flow cannot be held steady. This guide goes through the sizing calculation one step at a time, using one formula, one unit conversion and a few limits that matter for plastic piping in particular.
What needs to be known first
Four numbers are needed before any calculation is started:
If the fluid is not water, the specific gravity can be taken from the supplier's data sheet. The pressure drop is usually decided by the pump or the head available. It is a design choice and not something that can be read off a valve.
Step 1: Work out the required Cv
Cv is the flow coefficient of a valve. It is defined as the number of US gallons per minute of water, at 60°F, that will pass through a fully open valve with a pressure drop of 1 psi. A valve with a Cv of 100 passes 100 gpm at 1 psi [1]. For liquids, the required Cv is found with this formula [1][2]:
A worked example from one of the sources: to pass 200 gpm of water with a 4 psi drop, Cv = 200 × √(1.0 ÷ 4) = 100, so a valve with a rated Cv of 100 or higher is required [1]. The same formula with other numbers works the same way. For 50 gpm of water and an allowed drop of 2 psi, Cv = 50 × √(1 ÷ 2), which is about 35.
Two limits are worth remembering. The formula is meant for non-flashing liquids. Gases, steam, flashing liquids and two-phase flow need other methods described in ISA/IEC 60534 [1].
If the data sheet gives Kv
Valves sold outside North America are often rated in Kv. Kv is the flow of water in cubic metres per hour at a pressure drop of 1 bar [3]. The conversion is Cv = Kv × 1.156, and Kv = Cv × 0.865 [3]. A metric form of the liquid formula also exists: Cv = 11.6 × q × √(SG ÷ dp), where q is in m³/h and dp is in kPa [2].
Step 2: Check the flow velocity
A valve that has enough Cv can still be a poor choice if the fluid moves too fast through the pipe. For PVC pipe, a common guideline is to keep water velocity at 5 ft/s unless special measures are taken against water hammer, and most experts agree it should never go above 10 ft/s [5]. A University of Florida extension bulletin gives the same limits [4]. On pump suction lines, a lower range of 2 to 3 ft/s is recommended to avoid cavitation [5].
Velocity can be found from the flow and the inside diameter. With Q in gpm and the inside diameter d in inches, v (ft/s) ≈ 0.4085 × Q ÷ d². The constant comes from unit conversion and is not taken from any of the sources.
As an example, take 50 gpm in a pipe with a 2.0 inch inside diameter (an illustration, not product data). The velocity is 0.4085 × 50 ÷ 4, or about 5.1 ft/s. That is just above the usual guideline, so a larger line would be worth considering before the valve is selected. The pipe's actual inside diameter depends on its schedule and manufacturer, so it should be taken from the pipe's own data.
Step 3: Allow for water hammer
Surge pressure is created when flow is stopped or changed suddenly. Quick valve operation, pump starts and stops, and rapid air release are the usual causes [4]. Plastic pipe is not immune, and the numbers can be large.
This matters most for actuated valves. Pneumatic and electric actuators can close a valve much faster than a hand lever, so the closing time of the actuator should be checked against the surge limits of the line. Yukon lists both pneumatic and electric actuated true union ball valves.
Step 4: Compare the result with the valve's rated Cv
Once the required Cv is known, a valve is chosen whose fully open Cv is higher than that figure [1]. A bigger margin is not automatically better.
For valves that regulate flow, the normal operating point is best placed at 60 to 80% of valve travel, which leaves room to increase flow later [1]. Another source recommends 60 to 80% open at maximum flow, and not much below 20% open at minimum flow [6]. An oversized valve working near 10% open can hunt and oscillate [1]. Oversized valves also cost more and are very sensitive, since a small movement of the stem makes a large change in flow. In one comparison with 1% positioning, a properly sized 3-inch valve held flow within 8 gpm, while a 6-inch valve held it only within 20 gpm [6].
Line size is a related question. For control service, full ball and high-performance butterfly valves are usually two sizes smaller than the line, and a valve smaller than half the line size, or larger than the line size, is considered poor piping practice [6]. That advice was written for control valves. For plain on/off isolation, the main question is whether the pressure drop across a fully open valve is acceptable, and the Cv calculation answers that.
Cv figures are published by the manufacturer for each valve type and size. The Yukon product pages for the UPVC and CPVC true union ball valves do not list Cv values, so those can be requested from the team through the contact page or looked up in the product catalogue.
Step 5: Confirm pressure and temperature
Flow is only half of the check. The valve must also suit the pressure and temperature of the line. As listed on its product page, the Yukon UPVC 2-way true union ball valve is available from 1/2" to 4", with a working pressure of PN 10 and a working temperature of -25 to 80°C [7]. The CPVC version is also listed from 1/2" to 4" and PN 10, with a working temperature of -20 to 110°C [8]. The pages do not give pressure ratings at higher temperatures, so those figures should be confirmed before a hot line is specified. More background is given in the temperature rating guide and the UPVC vs CPVC vs PP comparison.
The whole method in one table
| Step | Question | What to use |
| 1 | How much Cv is needed? | Cv = Q × √(G ÷ ΔP) [1][2] |
| 2 | Is the velocity acceptable? | About 5 ft/s as a guideline, never above 10 ft/s [4][5] |
| 3 | Can surge be controlled? | Closing time of at least 10 s, 30 s or more preferred [4] |
| 4 | Is the valve the right size? | Rated Cv above the requirement; 60 to 80% open for control duty [1][6] |
| 5 | Does it suit the line? | Pressure and temperature from the manufacturer's data [7][8] |
Common mistakes
Some of these are covered further in Yukon's guide to the top 5 mistakes when choosing industrial valves. If the type of valve is still undecided, the article on ball vs butterfly valves compares the two. The full range can be browsed in the ball valve, butterfly valve and non-return valve categories.